The X-COM Systems NTDS Protocol Analyzer System reaches a new level of protocol analysis capability by providing insight into protocol, error, timing, and waveform analysis. The system includes an X-COM NTDS Type E Protocol Interface Module, a Tektronix TLA5000 Series Logic Analyzer, two TLA P6434 Probes, and custom disassembler software.
Integrated together, these analysis tools quickly and easily let system engineers, sofware developers and technicians monitor and capture NTDS serial (MIL-STD-1397C Type E) traffic between two NTDS devices while retaining full signal integrity without interrupting the data path.
Features
-
Professional Grade - X-COM's interface design and custom software enable customers to take advantage of all the proven test and measurement capabilities of Tektronix analyzers or oscilloscopes.
-
User-Defined Triggering - Triggering can be set to occur by timing, data, event, sequence, fault, transition, or other custom defined options.
-
Easy-to-Use - Custom designed software provides a highly detailed menu-driven user interface.
-
Ethernet-Ready Analyzer - Optional Ethernet Analyzer upgrade available.
-
Real-Time Acquisition - Data can be captured and triggered in real-time at an industry-leading 125ps resolution. Realtime acquisition is up to eight times faster than most systems currently available.
-
Transparent - Preserves the original signal path's integrity without introducing latency or signal loss regardless of whether the Protocol Interface Module is powered on or off.
-
Flexible Data Management - Captured data can be viewed, exported, printed, compared to previously collected data, or stored for later use.
|
The NTDS Protocol Analyzer System connects to an NTDS channel, between two NTDS devices, allowing for real-time data analysis and/or capture. The device allows network operators and test managers to conveniently monitor and troubleshoot NTDS traffic in order to:
|
-
Analyze hardware and software issues
-
Evaluate timing
-
Verify if protocol complies with requirements
-
Optimize code
-
Monitor peak load effects on system performance
More than just a common PC-based protocol analyzer, the NTDS Protocol Analyzer System is a professional-grade analysis tool that provides the most accurate and complete window into the signal makeup of NTDS communications.
|
 |
Applications
Software
Specifications
Ordering
NTDS Protocol Analyzer System Typical Application
Custom Software
In cooperation with Tektronix, custom software was developed by X-COM for the NTDS Protocol Interface Module to interface with Tektronix TLA5000 and TLA700 series analyzers.
|
Software features include: |
General
• Easy-to-Use TLA Interface
• Export and Print capabilities
• Data displayed in hexadecimal, octal or binary formats |
|
Data Collection
• Timestamping at 125ps resolution
• Frame Type Notification
• Error Notification
• Frame Burst Notification |
Capture and Filtering Modes
• Real-time
• SIS/SOS control frame filters
• User-definable
• Pre and Post Capture Filtering |
|
Triggering
• Timing
• Event
• Fault
• Transition
• Data
• Sequence
• or User-Defined |

Captured data is decoded and displayed for efficient analysis.

Tektronix TLA Logic Analyzers enable data to be viewed in numerous formats including timing waveforms, graphs, and histograms.
Specifications
|
NTDS Protocol Interface Module |
|
Interface
|
MIL-STD-1397C Type E
|
|
Size
|
5" L x 8.25" W x 3.5" H
|
|
Weight
|
Approximately 5 lbs.
|
|
Ports
|
-
Four MIL-STD-1397C Type E
-
Two Mictor Connectors
-
RS-232
-
10/100 BaseT (optional)
|
|
Monitor
|
-
Tektronix TLA5000 or TLA700 Series Logic Analyzers
-
Tektronix Oscilloscope (Optional)
|
|
Power
|
Standard IEC 115 VAC
|
|
Logic Analyzer |
|
Model
|
-
TLA5000 Series - TLA5202, TLA5203, or TLA5204
-
Size: 11.35" L x 17.5" W x 11.2" H
-
Weight: Approximately 26 lbs.
-
TLA700 Series - TLA715 or TLA721
-
Size: 17.5" L x 17" W x 9.25" H (TLA715)
26.5" L x 16.7" W x 13.65" H (TLA721)
-
Weight: Approximately 25 lbs. (TLA715)
Approximately 50 lbs. (TLA721)
|
|
Timestamping
|
51-Bits at 125 ps resolution - (3.25 days duration)
|
|
Memory Acquisition
|
8Mb-64Mb (configuration-dependant)
|
Product Comparison
|
Protocol Analysis
|
|
|
NTDS Protocol Analyzer System
|
Other Products
|
|
Channel ID
|
Yes
|
Yes
|
|
Frame Type
|
Yes
|
Yes
|
|
Parity Notification
|
Yes
|
Yes
|
|
Burst Notification
|
Yes
|
Yes
|
|
Error Analysis
|
|
Length Error
|
Yes
|
|
|
Parity Error
|
Yes
|
|
|
Timing Analysis
|
|
100ns Resolution
|
Yes
|
Yes
|
|
125ps Resolution
|
Yes
|
|
|
Waveform Analysis
|
|
Rise Fall Times
|
Yes
|
|
|
Distortion & Ringing
|
Yes
|
|
|
Impedance Anomalies
|
Yes
|
|
|
The NTDS Protocol Analyzer System offers more capabilities than other products currently available.
|
Ordering Information
|
NTDS Protocol Interface Module
|
|
NTDS Protocol Analyzer System Disassembler Software
|
|
NTDS Protocol Analyzer System*
System includes: X-COM NTDS Type E Protocol Interface Module, Tektronix Logic Analyzer, two P6434 Probes, and disassembler software.
|
|
NTDS Protocol Analyzer System with Oscilloscope*
System includes: X-COM NTDS Type E Protocol Interface Module, Tektronix Logic Analyzer, Tektronix Oscilloscope, associated cables, and disassembler software.
|
|
*X-COM offers custom packages with any compatible Tektronix Logic Analyzer or Oscilloscope.
|
|
|
Compatible Tektronix Logic Analyzers
-
TLA5000 Series (TLA5202, TLA5203, and TLA5204)
-
TLA700 Series (TLA715 and TLA721)
|
Compatible Tektronix Logic Oscilloscopes
-
THS700
-
TDS3000B
-
TDS5000B
-
TDS6000B
-
TDS7000B
|
|
Accessories
|
|
Logic Analyzer Probes
|
P6434 high-density, passive probe with AMP Mictor connector
|
|
Logic Analyzer Probe Type
|
Single-ended Data
Single-ended Clock
(Mictor 34-channel Qty 2)
|
|
Software
|
Loads onto Logic Analyzer from Disassembler Software CD
|
|
Options
|
|
Oscilloscope
|
Compatible with many Tektronix Oscilloscopes including TDS3000B/ 5000B/6000B/7000B and all 700 series. Call for complete list.
|