CPG-2110 Continuous Playback Generator
Converts digital I & Q waveform samples to analog I & Q waveforms

CPG-2110 Continuous Playback Generator
Part #: CPG-2110
The CPG-2110, Continuous Playback Generator, converts digital I & Q waveform samples to analog I & Q waveforms. These are used to drive the I & Q inputs of industry leading Vector Signal Generators (VSG) to modulate an RF carrier and recreate an RF spectrum. Using X-COM's graphical user interface IQC control software, users select an I & Q file for playback. The files can be those directly captured and saved by an X-COM IQC-2110. Alternatively, the captured data can be post processed with X-COM's RF Editor or Spectro-X software and the modified waveform can be saved and played through the CPG-2110.
IQC Control provides the operator several waveform playback options. Files can be played in their entirety, or repeated a user selectable number of times, or segments of files can be played. Segment start and stop times can be designated based on the selection of file markers from pull-down menus, markers plus time offsets or time since file start. The markers are inserted in the I&Q file as a result of trigger events received during the data capture from external devices.
Features
-
150 MHz Playback BW ensures utility of investment even as future RF systems and devices utilize more complex modulation schemes, higher order error correction coding and higher information rates
-
Looped playback of files, or precisely defined file segments, provides an extremely powerful tool for diagnosing and correcting communications errors caused by intermittent or short duration channel anomalies.
-
Equipment can be tested, and performance compared, using waveforms and spectra played by the CPG-2110 that are consistent in amplitude, phase, spectral shape and occupied bandwidth.
-
High fidelity and repeatability of output allows a CPG-2110 to be used as a replacement for a "Golden" radio in manufacturing.
-
Compatibility with a wide variety of industry leading VSG's minimizes the need to purchase a specialized VSG just for waveform playback
Applications
Specifications
Compatibility
Accessories
Applications
-
Electronic Warfare - Visualize and post process broad segments of the battlefield spectrum to design robust communications networks.
-
Wireless Comminications - Capture, identify and play back waveforms or create new ones fundamental to the testing and development of satellite and terrestrial, voice, data and telemetry equipment and networks.
-
Spectrum Management - Monitor spectrum usage and supplement the use of spectrum snapshots and tedious power surveys with long duration, geo-tagged, time-stamped spectral recordings.
-
Radar - Capture wide bandwidths over extended time periods to analyze radar effectiveness. Create and test new waveforms to improve performance.
-
Survelliance - Determine usage patterns, intercept transmissions and correlate data files to receiver locations for military, drug interdiction and homeland security applications.
Specifications
|
Input Data Rate
|
Up to 600 MB/second sustained (300 MB/s I & 300 MB/s Q from X-COM IQC-2110)
|
|
Playback Bandwidth
|
20KHz. ≤ BW ≤ 150MHz.
(Usually set automatically to correspond with IQC-2110 capture BW)
|
|
Signal Interfaces, Digital I & Q Inputs
|
16 bit, LVDS, via 26 pin MDR connectors for each I & Q stream
|
|
Analog I & Q Output
|
+/-0.5 V pk-pk analog I & Q
|
|
File Start/Stop Location Options
|
-
First sample block(Start)/last sample block (Stop)
-
Any of 510 file markers generated by occurence of external trigger events during data capture (Start)/Any subsequent file marker (Stop). User selectable from pull-down menu in IQC Control GUI.
-
File Marker + Time Offset (Start)/The same File Marker +next highest Time Offset or any subsequent File Marker + Time Offset (Stop).
-
Time Since File Start Time (Start & Stop)
-
Smallest Time increment or offset = 1 sample, (See Compatibility tab Table A for sample rates)
|
|
File Repetition
|
Single Play or End to Beginning Loop (number of loops user specified in IQC Control GUI)
|
|
File Size
|
Limited only be size of RAID5 disk array used for storage. File time duration can be up to days in length
|
|
Control |
|
Remote
|
Windows XP or Windows 7 OS PC with minimum of 50 Mbytes free disk space, 1GByte RAM, running X-COM IQC remote controller software version 2.2.0.24 or later. Interconnect between PC, CPG-2110 and external VSG via Gigabit Ethernet, RJ-45 cables and Ethernet switch.
|
|
Front Panel
|
System ON/OFF, momentary push button
|
|
Power
|
110/VAC, 50/60 Hz, 100W max.
|
|
Size
|
19" Rackmount; 2U
|
|
Weight
|
25 lbs.
|
|
Environmental |
|
Temperature
|
Operating: +5 to +50 degrees Celsius
Storage: -20 to +70 degrees Celsius CPG-2110)
-40 to +70 degrees Celsius (External Memory), max gradient 20% /hr.
|
|
Humidity
|
(The values below assume no condensation on the drives used for file storage by the CPG-2110)
Operating: 5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
Non-operating: 5% to 95% non-condensing relative humidity.
|
|
Effective Altitude
|
(relative to sea level)
Operating: –200 to +10,000 feet (–60.96 to +3,048 meters)
Non-operating –200 to +40,000 feet (–60.96 to +12,210 meters)
|
Equipment Compatibility
Input: X-COM IQC2110
Output Vector Signal Generators:
-
Agilent: Agilent PSG, MXG, and ESG
-
Rohde & Schwarz: SMBV, SMU, SMJ Series
Table A - Sample Rates
|
Agilent PXA, MXA, EXA
Signal Analyzer
|
|
Bandwidth (Hz)
|
Sample Rate
|
|
128 kHz - 40 MHz
|
1.25 * BW
|
|
Rohde & Schwarz
FSV (28 MHz)
FSG, FSQ (28 MHz)
FSV (40 MHz)
|
|
Bandwidth (Hz)
|
Sample Rate
|
|
28,000,000
|
44,800,000 (FSV)
|
|
28,000,000
|
50,000,000
|
|
40,000,000
|
64,000,000
|
|
|
|
|
Tektronix: RSA5100A
|
|
Bandwidth (Hz)
|
Sample Rate
|
|
85,000,000
|
150,000,000
|
|
40,000,000
|
75,000,000
|
|
25,000,000
|
50,000,000
|
|
20,000,000
|
25,000,000
|
|
10,000,000
|
12,500,000
|
|
5,000,000
|
6,250,000
|
|
2,000,000
|
3,125,000
|
|
1,000,000
|
1,562,500
|
|
500,000
|
781,250
|
|
200,000
|
390,625
|
|
100,000
|
195312.5
|
|
50,000
|
97656.25
|
|
20,000
|
48828.125
|
|
10,000
|
24414.0625
|
|
5,000
|
12207.03125
|
|
2,000
|
3051.7578125
|
|
1,000
|
1525.87890625
|
|
500
|
762.939453125
|
|
200
|
381.4697265625
|
|
100
|
190.73486328125
|
|
Tektronix: RSA6100A
|
|
Bandwidth (Hz)
|
Sample Rate
|
|
110,000,000
|
150,000,000
|
|
60,000,000
|
75,000,000
|
|
40,000,000
|
50,000,000
|
|
20,000,000
|
25,000,000
|
|
10,000,000
|
12,500,000
|
|
5,000,000
|
6,250,000
|
|
2,000,000
|
3,125,000
|
|
1,000,000
|
1,562,500
|
|
500,000
|
781,250
|
|
200,000
|
390,625
|
|
100,000
|
195312.5
|
|
50,000
|
97656.25
|
|
20,000
|
48828.125
|
|
10,000
|
24414.0625
|
|
5,000
|
12207.03125
|
|
2,000
|
3051.7578125
|
|
1,000
|
1525.87890625
|
|
500
|
762.939453125
|
|
200
|
381.4697265625
|
|
100
|
190.73486328125
|
|
Accessories
|
X-COM SigAnalyst Workstation
|
-
Powerful turn-key digital signal processing system
-
Advanced signal creation and analysis with software tool kit
|
|
X-COM Spectro-X and RF Editor
|
-
Rapidly search and visualize large data sets to locate and analyse hard to find signals
-
Filter, shift-in-frequency and resample individual files to build valuable signal libraries
|
|