©2012 - X Com Terms of use.



12345-B Sunrise Valley Drive
Reston, Virginia 20191
Phone: (703) 390-1087
 
Products > Multi-Channel Waveform Generators > CPG-2110 Continuous Playback Generator

CPG-2110 Continuous Playback Generator

Converts digital I & Q waveform samples to analog I & Q waveforms

CPG-2110 Continuous Playback Generator

CPG-2110 Continuous Playback Generator


Part #: CPG-2110

 Downloads
IQC-2110 User Manual
Note:
This User Manual contains sections for the CPG-2110

Part #: CPG-2110

The CPG-2110, Continuous Playback Generator, converts digital I & Q waveform samples to analog I & Q waveforms. These are used to drive the I & Q inputs of industry leading Vector Signal Generators (VSG) to modulate an RF carrier and recreate an RF spectrum. Using X-COM's graphical user interface IQC control software, users select an I & Q file for playback. The files can be those directly captured and saved by an X-COM IQC-2110. Alternatively, the captured data can be post processed with X-COM's RF Editor or Spectro-X software and the modified waveform can be saved and played through the CPG-2110.

IQC Control provides the operator several waveform playback options. Files can be played in their entirety, or repeated a user selectable number of times, or segments of files can be played. Segment start and stop times can be designated based on the selection of file markers from pull-down menus, markers plus time offsets or time since file start. The markers are inserted in the I&Q file as a result of trigger events received during the data capture from external devices.

Features

  • 150 MHz Playback BW ensures utility of investment even as future RF systems and devices utilize more complex modulation schemes, higher order error correction coding and higher information rates
  • Looped playback of files, or precisely defined file segments, provides an extremely powerful tool for diagnosing and correcting communications errors caused by intermittent or short duration channel anomalies.
  • Equipment can be tested, and performance compared, using waveforms and spectra played by the CPG-2110 that are consistent in amplitude, phase, spectral shape and occupied bandwidth.
  • High fidelity and repeatability of output allows a CPG-2110 to be used as a replacement for a "Golden" radio in manufacturing.
  • Compatibility with a wide variety of industry leading VSG's minimizes the need to purchase a specialized VSG just for waveform playback
Applications
Specifications
Compatibility
Accessories

Applications

  • Electronic Warfare - Visualize and post process broad segments of the battlefield spectrum to design robust communications networks.
     
  • Wireless Comminications - Capture, identify and play back waveforms or create new ones fundamental to the testing and development of satellite and terrestrial, voice, data and telemetry equipment and networks.
     
  • Spectrum Management - Monitor spectrum usage and supplement the use of spectrum snapshots and tedious power surveys with long duration, geo-tagged, time-stamped spectral recordings.
     
  • Radar - Capture wide bandwidths over extended time periods to analyze radar effectiveness. Create and test new waveforms to improve performance.
     
  • Survelliance - Determine usage patterns, intercept transmissions and correlate data files to receiver locations for military, drug interdiction and homeland security applications.

Specifications

Input Data Rate
Up to 600 MB/second sustained (300 MB/s I & 300 MB/s Q from X-COM IQC-2110)
Playback Bandwidth
20KHz. ≤ BW ≤ 150MHz.
(Usually set automatically to correspond with IQC-2110 capture BW)
Signal Interfaces, Digital I & Q Inputs
16 bit, LVDS, via 26 pin MDR connectors for each I & Q stream
Analog I & Q Output
+/-0.5 V pk-pk analog I & Q
File Start/Stop Location Options
  • First sample block(Start)/last sample block (Stop)
  • Any of 510 file markers generated by occurence of external trigger events during data capture (Start)/Any subsequent file marker (Stop). User selectable from pull-down menu in IQC Control GUI.
  • File Marker + Time Offset (Start)/The same File Marker +next highest Time Offset or any subsequent File Marker + Time Offset (Stop).
  • Time Since File Start Time (Start & Stop)
  • Smallest Time increment or offset = 1 sample, (See Compatibility tab Table A for sample rates)
File Repetition
Single Play or End to Beginning Loop (number of loops user specified in IQC Control GUI)
File Size
Limited only be size of RAID5 disk array used for storage. File time duration can be up to days in length
Control
Remote
Windows XP or Windows 7 OS PC with minimum of 50 Mbytes free disk space, 1GByte RAM, running X-COM IQC remote controller software version 2.2.0.24 or later. Interconnect between PC, CPG-2110 and external VSG via Gigabit Ethernet, RJ-45 cables and Ethernet switch.
Front Panel
System ON/OFF, momentary push button
Power
110/VAC, 50/60 Hz, 100W max.
Size
19" Rackmount; 2U
Weight
25 lbs.
Environmental
Temperature
Operating:  +5 to +50 degrees Celsius
Storage:  -20 to +70 degrees Celsius CPG-2110)
-40 to +70 degrees Celsius (External Memory), max gradient 20% /hr.
Humidity
(The values below assume no condensation on the drives used for file storage by the CPG-2110)
Operating:  5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
Non-operating:  5% to 95% non-condensing relative humidity.
Effective Altitude
(relative to sea level)
Operating:  –200 to +10,000 feet (–60.96 to +3,048 meters)
Non-operating  –200 to +40,000 feet (–60.96 to +12,210 meters)
 

Equipment Compatibility

Input: X-COM IQC2110

Output Vector Signal Generators:
  • Agilent: Agilent PSG, MXG, and ESG
  • Rohde & Schwarz: SMBV, SMU, SMJ Series

Table A - Sample Rates

Agilent PXA, MXA, EXA
Signal Analyzer
Bandwidth (Hz)
Sample Rate
128 kHz - 40 MHz
1.25 * BW
Rohde & Schwarz
FSV (28 MHz)
FSG, FSQ (28 MHz)
FSV (40 MHz)
Bandwidth (Hz)
Sample Rate
28,000,000
44,800,000 (FSV)
28,000,000
50,000,000
40,000,000
64,000,000
 
Tektronix: RSA5100A
Bandwidth (Hz)
Sample Rate
85,000,000
150,000,000
40,000,000
75,000,000
25,000,000
50,000,000
20,000,000
25,000,000
10,000,000
12,500,000
5,000,000
6,250,000
2,000,000
3,125,000
1,000,000
1,562,500
500,000
781,250
200,000
390,625
100,000
195312.5
50,000
97656.25
20,000
48828.125
10,000
24414.0625
5,000
12207.03125
2,000
3051.7578125
1,000
1525.87890625
500
762.939453125
200
381.4697265625
100
190.73486328125
Tektronix: RSA6100A
Bandwidth (Hz)
Sample Rate
110,000,000
150,000,000
60,000,000
75,000,000
40,000,000
50,000,000
20,000,000
25,000,000
10,000,000
12,500,000
5,000,000
6,250,000
2,000,000
3,125,000
1,000,000
1,562,500
500,000
781,250
200,000
390,625
100,000
195312.5
50,000
97656.25
20,000
48828.125
10,000
24414.0625
5,000
12207.03125
2,000
3051.7578125
1,000
1525.87890625
500
762.939453125
200
381.4697265625
100
190.73486328125

Accessories

X-COM SigAnalyst Workstation
  • Powerful turn-key digital signal processing system
  • Advanced signal creation and analysis with software tool kit
X-COM Spectro-X and RF Editor
  • Rapidly search and visualize large data sets to locate and analyse hard to find signals
  • Filter, shift-in-frequency and resample individual files to build valuable signal libraries